Kruger TDA Series - Direct Driven Tube Axial Fan
Kruger TDA Series - Direct Driven Tube Axial Fan (Installation)
Download Files
KrugerVentProject_20231030_103036_(TDA_630)_(30-10-2023)(NO_COMPANY_NAME).pdf (73.57 KB)
TDA_900_14AA_(24-7-2023).pdf (142 KB)
TDA_710__(18-7-2023).pdf (143.42 KB)
Kruger_TDA_(30-6-2023).pdf (410.04 KB)
KrugerVentProject_20231030_103036_(TDA_630)_(30-10-2023)(NO_COMPANY_NAME).pdf (73.57 KB)
TDA_900_14AA_(24-7-2023).pdf (142 KB)
TDA_710__(18-7-2023).pdf (143.42 KB)
Kruger_TDA_(30-6-2023).pdf (410.04 KB)
Kruger TDA Series - Direct Driven Tube Axial Fan
Model
KRUGER TDA 355/9AA/5-5/18 510CFM @ 0.26''WG 0.37 (IE1) KW / 4P / F (IP55) (415V/3PH/50HZ)(RPM:1450) (230311GY-1) (W/O BRACKET)
Removal Of Impeller Fan (TDA 1000)
Note
Tda-v have guided vane , while TDa is normal without guided vane.
Model
KRUGER TDA-M 560/5/32.5/5ZL/ALU 3500CFM @ 0.5''WG 0.75 (IE1) KW / 4P / F (2211572GY-01) (W/O BRACKET)
KRUGER TDA 1000/14AA/9-9/20 62000CMH @ 12mmWG 15 (IE1) KW / 4P / CLASS F Fan (Replaced:TDA-M 1000)KRUGER TDA 355/9AA/5-5/18 510CFM @ 0.26''WG 0.37 (IE1) KW / 4P / F (IP55) (415V/3PH/50HZ)(RPM:1450) (230311GY-1) (W/O BRACKET)
KRUGER TDA 400/9AA/5/16 0.37 (IE1) KW / 4 Pole / Class H (W/O BRACKET)
KRUGER TDA 450/9AA/5-5/18 0.37 (IE1) / 4P / CLASS F (W/O BRACKET)
KRUGER TDA 500/12AA/7-7/16 0.37 (IE1) / 4P / CLASS F (W/O BRACKET)
KRUGER TDA 500/12AA/7-7/24 2000CFM @ 0.8''WG 0.55 (IE1) KW / 4P / CLASS F (W/O BRACKET)(2306398GA-1)
KRUGER TDA 500/9AA/5-5/20/F 2.2KW(IE1)/2P/CLASS H FAN ONLY (415V/3PH/50HZ)(RPM:2850)(7650CFM)(FIRE RATED)(W/O BRACKET)
KRUGER TDA 560/12AA/7-7/38 7000CFM @ 0.4''WG 1.5 (IE1) KW / 4 Pole / Class F (W/O BRACKET)
KRUGER TDA 560/9AA/7-7/28 5500CFM @ 0.4''WG 0.75 (IE1) KW / 4 Pole / Class F (W/O BRACKET)
KRUGER TDA 630/12AA/7-7/16/F 1.1/0.28 (IE1) KW / 4/8P / CLASS H (IP55) (W/O SPRING ISOLATOR) (W/O BRACKET)(2310422 GA-1)
KRUGER TDA 630/12AA/9-9/14 0.75 (IE1) KW / 4P / CLASS F (C/W SPRING ISOLATOR) (W/O BRACKET) 2308163GA-01
KRUGER TDA 630/12AA/7-7/16/F 1.1/0.28 (IE1) KW / 4/8P / CLASS H (IP55) (W/O SPRING ISOLATOR) (W/O BRACKET)(2310422 GA-1)
KRUGER TDA 630/12AA/9-9/14 0.75 (IE1) KW / 4P / CLASS F (C/W SPRING ISOLATOR) (W/O BRACKET) 2308163GA-01
KRUGER TDA 800/14AA/8-8/28 (AL-ALU. BLADE MAT) 5.5 (IE1) KW / 4P / CLASS F (W/O MOTOR) (W/O BRACKET)
KRUGER TDA 900/14AA/7-7/12 (AL-ALU. BLADE MAT) 4.0 (IE1) KW / 4P / CLASS F ((W/O BRACKET)
Note
Tda-v have guided vane , while TDa is normal without guided vane.
For commercial and industrial application where large volume of air is required at moderate pressure.
High temperature (up to 400°C/2 Hours) in accordance with EN12101-3 certification by TÜV SÜD a third party globally renowned testing and certification organisation.
All impellers are statically and dynamically balanced to ISO1940 and AMCA204 - G2.5 Standards.
Actual Installation